Tips on Buying a House Built in 1980-2000

Tips on Buying a House Built in 1980-2000

What to Look Out for with Buying Houses from the 1980’s to 1990’s

In time, innovations and products that go into building a home have actually progressed. Occasionally particular items or products were located to be bothersome, and should be changed. The issues vary from plumbing leaks to fires, and these essential items need to be noted with any Columbia house inspection.

With acquiring a home built in between 1980 to 1999, there are some items that might be show up with the home inspection. These things must be taken into consideration to be possible problems, and an expert should be gotten in touch with to evaluate the plumbing and HVAC systems, to make sure the house will be a safe environment.Polybutylene Plumbing Pipes

Polybutylene plumbing pipes were used a lot in the 1980’s and 1990’s. At the time, it was thought to be a rather large advancement for the following reasons. One, it was much easier and more affordable to set up than conventional copper pipes. Also, it will not corrode like metal pipes will eventually.

The issue is that the plumbing connections fell short and caused millions in property damage for residents. Because of this a recall was released and a substantial settlement happened for many individuals who had this kind of plumbing installed. If this sort of piping is located during a home inspection, the inspector will most likely recommend having a re-pipe done.

Horizontal furnaces are another item that were used a lot and also were eventually recalled due to the possibility of fire. These were used in attics to help save space. Due to problems concerning discharges, NOx poles were mounted in a few of these heating systems. The heating systems were made with metal rods,NOx poles, located over the top of the burner ribbons. These were meant to minimize unsafe discharges from the furnace like a Catalytic Converter does in an automobile. The trouble is that they eventually break for they become brittle from getting so hot every time the furnace is operating. Once they deteriorate they can fall through the furnace bottom and start a fire.

There are a lot of heating systems that look similar to the ones recalled but they don’t have NOx poles inside. Because of the recall, lots of heating professionals will not work on these devices for responsibility reasons.

One more element that belongs to the HVAC system that did not work out well is the flexible duct. Prior to the 1980’s ducts were rigid, and wrapped with insulation. A brand-new adaptable duct was introduced that made it easier to install. This new versatile duct has a plastic tube that is held open with a coil of wire just like a large spring. The plastic it is wrapped in was not checked for UV resistance damages and also though it remains in an attic room, light still filters in through vents. Sunlight coming in through an attic vent has degraded the grey plastic sleeve of the air duct. This has actually permitted the fiberglass insulation to fall away from the clear plastic tube that comprises the actual duct. While no air is running away the air duct, the absence of insulation lowers the efficiency of the HVAC system. This problem could occasionally be fixed, replacing the air duct is the best solution.

These are a few of the troubles that we generally discover in home constructed in the 1980’s and 1990’s. Not all residences have these elements. It is impossible for home inspectors to be aware of every single recall that has happened over the years. Do not hesitate to let us know of any issues you are specifically concerned about while we perform your home inspection in Columbia SC.